HIGH POWER TRAVELING WAVE TUBE FOR DBS GROUND TERMINALS
LD7237
DBS Band, 400 W CW, PPM FOCUSING, HIGH POWER GAIN
GENERAL DESCRIPTION
NEC LD7237 is PPM-focused traveling wave tube designed for use as final amplifier in the earth-to-satellite communications transmitter. This is capable of delivering an output power of 400 W over the range of 17.3 to 18.1 GHz and provides a high power gain of 53 dB at 400 W output power. Furthermore, this is of rugged and reliable design offering long-life service. LD7237 is fully compatible with TH3694B.
FEATURES
TM High Power Gain The power gain is typically 53dB at 400 W level. TM Simple Cooling System The tube is forced-air-cooled, so that the cooling systems are greatly simplified. TM PPM Focusing The tube is PPM (Periodic Permanent Magnet)-focused, eliminating entirely the focusing power supplies and interlock circuits. TM Rugged Construction The tube is designed to be rugged, therefore it is suitable for the transportable systems. TM Long Life and High Stability The tube employs an advanced impregnated cathode with a low operating temperature for long life. TM Microdischarge Free The tube is carefully designed to be free from microdischarge in the electron gun for long term operation, therefore it is suitable for digital communication service.
For safe use of microwave tubes, refer to NEC document "Safety instructions to all personnel handling electron tubes" (ET0048EJVUM00)
The information in this document is subject to change without notice.
Document No. ET0159EJ2V1DS00 Date Published August 1998 M Printed in Japan
(c)
1996
LD7237
GENERAL CHARACTERISTICS
ELECTRICAL Frequency .................................................................................. 17.3 to 18.1 GHz Output Power ............................................................................ 400 W Heater Voltage ........................................................................... 6.3 V Heater Current ........................................................................... 1.4 A Type of Cathode ........................................................................ Indirectly heated, Impregnated Cathode Warm-up Time ........................................................... 300 s MECHANICAL Dimensions ................................................................................ See Outline Drawing Weight ........................................................................................ 6.0 kg approx. Focusing .................................................................................... Periodic Permanent Magnet Mounting Position .................................................................... Any Electrical Connections .............................................................. AMP 861647-8 multi-pin connector Heater, Heater-Cathode Helix, Anode, Collector and Thermal Protection RF Connections Input ................................................................................... Mates with SMA-Female Output ................................................................................ Mates with UBR-140 Flange Cooling ....................................................................................... Forced Air
2
LD7237
ABSOLUTE RATINGS
ELECTRICAL Min. Heater Voltage .................................................................. Heater Surge Current ...................................................... Heater Current .................................................................. Heater Warm-up Time ..................................................... Helix Voltage .................................................................... Helix Current .................................................................... Anode Voltage .................................................................. Anode Current .................................................................. Collector Voltage .............................................................. Cathode Current ............................................................... RF Drive Power ................................................................ Load VSWR ...................................................................... MECHANICAL Min. Temperature at output Flange ........................................ Air Flow ............................................................................ Ambient Temperature Storage ..................................................................... Operation .................................................................. -40 -10 +80 +50 C C - 195 Max. 100 - Unit C kg/hr 6.0 - - 300 9.5 - 8.55 - 4.0 - - - Max. 6.6 4.5 3.0 - 10.75 15 10.25 0.5 5.5 350 25 1.5 Unit V A A s kV mA kV mA kV mA mW
(Note 1, 2 and 3)
3
LD7237
TYPICAL OPERATION (Note 2, 3 and 5)
Unit Frequency ............................................................................... 17.3 to 18.1 Output Power ......................................................................... Heater Voltage (Note 4) ........................................................ Heater Current ........................................................................ Helix Voltage ........................................................................... Helix Current ........................................................................... Anode Voltage ........................................................................ Anode Current ........................................................................ Collector Voltage .................................................................... Cathode Current ..................................................................... Power Gain at small signal .................................................................. at rated output power ..................................................... Gain Variation at small signal ............................................... Gain Slope at small signal .................................................... AM-PM Conversion at small signal .................................................................. at rated output power ..................................................... 3rd Order Intermodulation (two equal carriers, 40 W total) ...................................... Cooling Air Flow .................................................................... Pressure Drop ......................................................................... 0.5 2.0 -32 195 650 /dB /dB dBc kg/hr Pa 58 53 2 0.01 dB dB dB/800 MHz dB/MHz 400 6.3 1.4 10 2 9.5 0.1 4.7 290 GHz W V A kV mA kV mA kV mA
Note 1 : Absolute rating should not be exceeded under continuous or transient conditions. A single absolute rating may be the limitation and simultaneous operation at more than one absolute rating may not be possible. Note 2 : The tube body is at ground potential in operation. Note 3 : All voltages are refferred to the cathode potential except the heater voltage. Note 4 : The optimum operating parameters are shown on a test performance sheet for each tube. Note 5 : These characteristics and operating values may be changed as a result of additional information or product improvement. NEC should be consulted before using this information for equipment design. This data sheet should not be referred to a contractual specification.
4
LD7237
LD7237 OUTLINE (Unit in mm)
AMP861647-8 MULTI-PIN CONNECTOR
900 50
85 MAX.
29 210 MAX.
RF INPUT SMA FEMALE
157 19 101 101 175 101
505 MAX.
178
4-M4
RF OUTPUT Mates with UBR-140 FLANGE
10- 6
6
110 MAX.
111 127 MAX.
55
87.5 MAX.
PIN CONNECTION 7 1 2 6 5 3 4
98
66
86
AMP861647-8 CONNECTOR 4-M3 83 AIR OUTLET PIN ASSIGNMENT Pin No. 1 2 3 4 5 6 7 LEAD NAME HEATER / CATHODE HEATER COLLECTOR THERMAL PROTECTION OPEN (NO CONNECTION) HELIX (GROUND) ANODE
NOTE THERMAL PROTECTION : N / C (Normally Closed) CONTACT
5
LD7237
6
LD7237
7
LD7237
No part of this document may be copied or reproduced in any form or by any means without the prior written consent of NEC Corporation. NEC Corporation assumes no responsibility for any errors which may appear in this document. NEC Corporation does not assume any liability for infringement of patents. copyrights or other intellectual property rights of third parties by or arising from use of a device described herein or any other liability arising from use of such device. No license, either express, implied or otherwise, is granted under any patents, copyrights or other intellectual property rights of NEC Corporation or others. While NEC Corporation has been making continuous effort to enhance the reliability of its Electronic Conponents, the possibility of defects cannot be eliminated entirely. To minimize risks of damage or injury to persons or property arising from a defect in an NEC Electronic Conponents, customers must incorporate sufficient safety measures in its design, such as redundancy, fire-containment, and anti-failure features. NEC devices are classified into the following three quality grades: "Standard", "Special", and "Specific". The Specific quality grade applies only to devices developed based on a customer designated "quality assurance program" for a specific application. The recommended applications of a device depend on its quality grade, as indicated below. Customers must check the quality grade of each device before using it in a particular application. Standard: Computers, office equipment, communications equipment, test and measurement equipment, audio and visual equipment, home electronic appliances, machine tools, personal electronic equipment and industrial robots Special: Transportation equipment (automobiles, trains, ships, etc.), traffic control systems, anti-disaster systems, anti-crime systems, safety equipment and medical equipment (not specifically designed for life support) Specific: Aircrafis, aerospace equipment, submersible repeaters, nuclear reactor control systems, life support systems or medical equipment for life support, etc. The quality grade of NEC devices is "Standard" unless otherwise specified in NEC's Data Sheets or Data Books. If customers intend to use NEC devices for applications other than those specified for Standard quality grade, they should contact an NEC sales representative in advance. Anti-radioactive design is not implemented in this product.


▲Up To Search▲   

 
Price & Availability of LD7237

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X